WORLD WIDE SHIPPING*

GM-171 Microscope Head (Binocular)

GM-171 Microscope Head (Binocular)

Motic SMZ140 Objective Lens-1.5X

Motic SMZ140 Objective Lens-1.5X

GM-171 Microscope Head (Trinocular)

Microscope Head

The SMZ171 stereo head is an excellent choice for jewelry and gemstone inspection at an affordable price. The parfocal zoom ratio is 6.7:1, offering a magnification range of 7x-50x with dual-sided zoom controls and a working distance of 110mm. The head is inclined 45° and includes linear sliding interpupillary adjustment of 50mm-75mm.

  • High Eyepoint widefield 10X/F.N.23 eyepieces come standard, offering dual dioptric adjustment and a broad field of view ranging from 30.67mm to 1.33mm. Optional eyepiece powers include 15X and 20X, for additional magnification of 75X and 100X respectively, without the loss of working distance. Finally, the microscope is available in a binocular or trinocular format to easily capture digital images for documentation, promotion or client use. Please note that a trinocular adapter is required to fit your camera.
  • The SMZ171 stereo head can be used with the Motic base (Sold Separately) or any other Universal microscope base (like - Gemax I.LED Microscope Base)
**This is Trinocular Head (Only) . Base and other parts are not included (Sold Separately)
$1,575.00
Availability: In stock
SKU
MRS002-H

Microscope Head

The SMZ171 stereo head is an excellent choice for jewelry and gemstone inspection at an affordable price. The parfocal zoom ratio is 6.7:1, offering a magnification range of 7x-50x with dual-sided zoom controls and a working distance of 110mm. The head is inclined 45° and includes linear sliding interpupillary adjustment of 50mm-75mm.

  • High Eyepoint widefield 10X/F.N.23 eyepieces come standard, offering dual dioptric adjustment and a broad field of view ranging from 30.67mm to 1.33mm. Optional eyepiece powers include 15X and 20X, for additional magnification of 75X and 100X respectively, without the loss of working distance. Finally, the microscope is available in a binocular or trinocular format to easily capture digital images for documentation, promotion, or client use. Please note that a trinocular adapter is required to fit your camera.
  • The SMZ171 stereo head can be used with the Motic base (Sold Separately) or any other Universal microscope base (like - Gemax I.LED Microscope Base)
**This is Trinocular Head (Only) . Base and other parts are not included (Sold Separately)
Write Your Own Review
You're reviewing:GM-171 Microscope Head (Trinocular)
Your Rating

Specifications: Motic Gem Microscope GM171-Trinocular

 

Model                                                         SMZ-171Bino                   SMZ-171Trino
Optical system Greenough
Observation angle 45°/ 60° 45°
Magnification range (standard) 0.75X--5X
Zoom ratio 1:6.7
Eyepiece  N-WF, high eye-point 10X(Ø23),  Diopter adjustable interchangeable with biological eyepieces
N-WF 12.5X(Ø18), 15X(Ø16),  20X(Ø13) optional
Interpupilary adjustment  48mm-75mm
Height of eye point 405mm
Working distance (standard) 110mm
Weight 6.2 kg (head 1.4kg)
C-Mount adapter / Trinocular head only
/ 0.5X, 0.65X, 1X adapters available
Photo adapter / SY10 photo adapter 2.5X, 4X photo eyepiece available
Auxiliary ESD objectives 0.3X [WD = 301mm], 0.5X [WD = 191.8mm], 0.63X [WD = 142.7mm],
0.75X [WD = 128.6mm], 1.5X [WD = 56.3mm ], 2.0X [WD = 38.6mm]
Dimension and weight
Length Width Height weight (Kgs)
Product
Package
Warranty: Lifetime Limited Warranty

Cautions :

  • Use:
    This microscope is to be used for observation purposes only.

 

  • Do not disassemble:
    Disassembly may lead to possible damage of the instrument and voidance of warranty. If a problem is discovered, please contact the Motic dealer nearest you.

 

  • Avoid getting burnt:
    Wait for the bulb and surrounding parts to cool down before changing. Keep flammable objects (gasoline, alcohol, cloth, paper, etc.) away from the bulb to avoid the possibility of a fire.

 

  • Check input voltage:
    The label on the back of the microscope clearly specifies the microscope’s input voltage which must be compatible with the local power supply. Using the microscope with a non-specified voltage rating can lead to damage of the instrument.

 

  • When changing the bulb please note:
    Only specified halogen bulbs and fluorescence tubes may be used. Before changing the bulb, turn off the power and unplug the power cable to avoid being electrocuted. When changing the bulb, do not let the bulb get dirty. The outer surface of the bulb must not be contaminated with dust or fingerprints etc.

 

  • Storage:
    Before moving the microscope, be sure the power is switched off.
    Microscope working temperature and humidity requirements:
    • Room temperature: 5°C ~ 35°C;
    • Maximum relative humidity: 65%

 

  • Operation:
    This microscope is a high precision instrument and must be handled and operated with extreme care. Jolting or aggressive operation can lead to damage of the instrument
We found other products you might like!